This question was closed without grading. Reason: No acceptable answer
Apr 28, 2019 10:07
5 yrs ago
2 viewers *
English term
start|stop V
English to Russian
Science
Chemistry; Chem Sci/Eng
потенциометрия
Здравствуйте! В параметрах системы перечисляетс следующее:
stopV: 10 мл
stop pH: откл.
stop EP: 9
EPC: 0.50
EP recognition: самое высокое
start V. (с точкой)
start V (без точки)
Помогите, пожалуйста, расшифровать.
stopV: 10 мл
stop pH: откл.
stop EP: 9
EPC: 0.50
EP recognition: самое высокое
start V. (с точкой)
start V (без точки)
Помогите, пожалуйста, расшифровать.
Proposed translations
(Russian)
5 | stop V: stop volume | Erzsébet Czopyk |
Proposed translations
1 hr
stop V: stop volume
>stop conditions
Stop conditions for the titration
If several stop conditions have been set, the criterion
which is met first applies.
Type of stop volume (abs., rel., OFF)
"abs.": absolute stop volume in mL.
"rel.": relative stop volume to sample size.
"OFF": stop volume switched off. Stop volume is not
monitored.
If "abs." is set:
Absolute stop volume (0...9999.99 mL)
If "rel." is set:
Factor for relative stop volume (0...±999999)
Calculated as: Stop V (in mL) = factor∗sample size
Stop at measured value (input range dependent on
measured variable:
pH: 0... ± 20.00, OFF
U, Ipol: 0... ± 2000 mV, OFF
Upol: 0... ± 200.0 µA, OFF)
<CLEAR> sets "OFF".
"OFF" means that the criterion is not monitored.
--------------------------------------------------
Note added at 1 hr (2019-04-28 11:38:54 GMT)
--------------------------------------------------
https://www.chem21.info/info/1174026/
Титрование до остановки условия
Метод конечной остановки можно использовать в том случае, когда точка эквивалентности отвечает изменению условий, соответствующих переходу системы от состояния с одним поляризованным электродом к состоянию с двумя деполяризованными электродами, а также в обратном случае.
--------------------------------------------------
Note added at 1 hr (2019-04-28 11:40:08 GMT)
--------------------------------------------------
https://www.chem21.info/info/1174018/
--------------------------------------------------
Note added at 1 hr (2019-04-28 11:43:10 GMT)
--------------------------------------------------
Overview of the titration modes
DET - Dynamic Equivalence point Titration
MET - Monotonic Equivalence point Titration
SET, KFT - Endpoint Titration
please download the document named "794 Basic Titrino" by Metrohm
Stop conditions for the titration
If several stop conditions have been set, the criterion
which is met first applies.
Type of stop volume (abs., rel., OFF)
"abs.": absolute stop volume in mL.
"rel.": relative stop volume to sample size.
"OFF": stop volume switched off. Stop volume is not
monitored.
If "abs." is set:
Absolute stop volume (0...9999.99 mL)
If "rel." is set:
Factor for relative stop volume (0...±999999)
Calculated as: Stop V (in mL) = factor∗sample size
Stop at measured value (input range dependent on
measured variable:
pH: 0... ± 20.00, OFF
U, Ipol: 0... ± 2000 mV, OFF
Upol: 0... ± 200.0 µA, OFF)
<CLEAR> sets "OFF".
"OFF" means that the criterion is not monitored.
--------------------------------------------------
Note added at 1 hr (2019-04-28 11:38:54 GMT)
--------------------------------------------------
https://www.chem21.info/info/1174026/
Титрование до остановки условия
Метод конечной остановки можно использовать в том случае, когда точка эквивалентности отвечает изменению условий, соответствующих переходу системы от состояния с одним поляризованным электродом к состоянию с двумя деполяризованными электродами, а также в обратном случае.
--------------------------------------------------
Note added at 1 hr (2019-04-28 11:40:08 GMT)
--------------------------------------------------
https://www.chem21.info/info/1174018/
--------------------------------------------------
Note added at 1 hr (2019-04-28 11:43:10 GMT)
--------------------------------------------------
Overview of the titration modes
DET - Dynamic Equivalence point Titration
MET - Monotonic Equivalence point Titration
SET, KFT - Endpoint Titration
please download the document named "794 Basic Titrino" by Metrohm