This ProZ/TV event is aimed at helping language professionals harness the power of AI tools to enhance your work and make informed business decisions for future success. In this event, we will delve into the world of AI-supported tools tailored specifically for language experts, providing practical insights and real-world examples.

Event access: this is a member-only event. If you are a ProZ.com paying member, register using the "Register for this event" button above and visit this page on the day and time of the event to attend (sessions will be broadcasted live). Not a member yet? Obtain unrestricted access to this event and to a full list of membership benefits by joining today. Check membership options »

Event recording: this event will be recorded and made available to ProZ.com Premium subscribers only (a few days after the event). If you are not a Premium subscriber, consider upgrading now. Check ProZ.com Premium »

Click for Full Participation

thermal time

German translation: thermische Ansprechzeit

GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW)
English term or phrase:thermal time
German translation:thermische Ansprechzeit
Entered by: Holger Remke

20:38 Apr 26, 2016
English to German translations [PRO]
Tech/Engineering - Electronics / Elect Eng / RCBO / Fehlerstromschutz
English term or phrase: thermal time
Bei der Beschreibung der Allgemeinen Merkmale eines Fehlerstromschutzschalters heißt es unter dem Punkt "Temperature de-rating:
RCBOs are designed and calibrated to carry their rated current and to operate within their designated thermal time/current zone at 30°C."
Holger Remke
Germany
Local time: 16:35
thermische Ansprechzeit
Explanation:
Ich denke, dass es sich um eine Verkürzung von "thermal response time" handelt. Das würde nämlich genau zur Funktion eines Fehlerstromschutzschalters passen, so wie ich das als Elektroingenieur kenne.
Elektronik und Elektrotechnik
EN thermal response time
DE thermische Ansprechzeit
http://iate.europa.eu/SearchByQuery.do
http://iate.europa.eu/SearchByQuery.do?method=searchDetail&l...


--------------------------------------------------
Note added at 4 days (2016-04-30 21:53:31 GMT)
--------------------------------------------------

Einzelheiten hierzu siehe https://de.m.wikipedia.org/wiki/Fehlerstrom-Schutzschalter

--------------------------------------------------
Note added at 5 days (2016-05-02 08:52:19 GMT)
--------------------------------------------------

Auszug:

Fehlerstrom-Schutzeinrichtungen jeder Bauform verhindern gefährlich hohe Fehlerströme gegen Erde und tragen so zur Reduzierung lebensgefährlicher Stromunfälle in Niederspannungsnetzen maßgeblich bei. Sie werden grundsätzlich den üblichen Überstromschutzeinrichtungen vorgelagert und zusätzlich zu diesen in den Niederspannungsverteilern installiert. Es gibt auch die Kombination in Form des RCBO, welcher die Funktion der Fehlerstrom-Schutzeinrichtung und des Leitungsschutzschalters in einem Gerät vereint. Für den Fehlerstromschutz einzelner Steckdosen in Altanlagen sind auch RCD-Steckdosen verfügbar.
:
Handelsüblich sind Fehlerstrom-Schutzschalter vom Typ A für Bemessungsfehlerströme von IΔn=10 mA, 30 mA, 100 mA, 300 mA, 500 mA und 1 A.[8] In der Praxis erfolgt die Auslösung bei handelsüblichen RCDs etwa bei 0,8 · IΔn.
Der Nichtauslösefehlerstrom IΔn0 beträgt 0,5 · IΔn. Ein Fehlerstrom-Schutzschalter darf erst oberhalb des halben Bemessungsfehlerstroms auslösen.

Abschaltzeiten:
• Für Fehlerstrom-Schutzschalter ohne Zeitverzögerung betragen die höchstzulässigen Abschaltzeiten 0,3 s bei einem Strom von IΔn, 0,15 s bei 2 · IΔn und 0,04 s bei 5 · IΔn. Damit wird ein Auslösen von (tödlichem) Kammerflimmern sehr unwahrscheinlich, kann allerdings nicht vollkommen ausgeschlossen werden, u. a. weil der physiologische Effekt eines Strompulses von der Phase des Herzschlags abhängt, in die er fällt.
• für selektive Fehlerstrom-Schutzschalter - also mit Zeitverzögerung - betragen die höchstzulässigen Abschaltzeiten 0,5 s bei einem Strom von IΔn, 0,2 s bei 2 · IΔn und 0,15 s bei 5 · IΔn
Nichtauslösezeiten sind nur für selektive Fehlerstrom-Schutzschalter definiert. Die kürzesten Nichtauslösezeiten betragen 0,13 s bei einem Strom von IΔn, 0,06 s bei 2 · IΔn und 0,05 s bei 5 · IΔn.
:
Um Selektivität zu erreichen, können Fehlerstrom-Schutzschalter in Reihe geschaltet werden. Dabei soll nur der dem fehlerbehafteten Stromkreis unmittelbar zugeordnete Fehlerstrom-Schutzschalter ohne Zeitverzögerung auslösen. Dieser Schutzeinrichtung wird zusätzlich ein Fehlerstrom-Schutzschalter mit Zeitverzögerung vorgeschaltet und ist mit dem Symbol für Selektivität gekennzeichnet. Eine Selektivität liegt vor, wenn:
• die kürzeste Nichtauslösezeit des vorgeschalteten Fehlerstrom-Schutzschalters mit Zeitverzögerung höher ist, als die höchste Abschaltzeit des nachgeschalteten Fehlerstrom-Schutzschalters ohne Zeitverzögerung
StörfestigkeitBearbeiten
Um ungewollte Auslösungen zu verhindern, werden Fehlerstrom-Schutzschalter mit Kurzzeitverzögerung verwendet. Ursachen für ungewollte Auslösungen können sein:
• Überspannungen durch Schalthandlungen und atmosphärischen Einwirkungen
• Ladevorgänge nach dem Zuschalten bzw. einer Laständerungen von kapazitiv bzw. induktiv wirkenden Betriebsmitteln
Die höchstzulässigen Abschaltzeiten sind gleich denen von Fehlerstrom-Schutzschaltern ohne Zeitverzögerung. Die Kennzeichnung erfolgt herstellerspezifisch, beispielsweise von:
• ABB mit der Angabe AP-R und der Verwendung des Begriffs kurzzeitverzögert
:
In den internationalen Gerätenormen werden folgende Bezeichnungen verwendet:
• RCCB = Residual Current operated Circuit-Breaker without over current protection, entspricht den reinen FI- bzw. DI-Schaltern, (ist gleichwertig zu RCD residual-current device)
• RCBO = Residual Current operated circuit-Breaker with integral Over current protection, entspricht den kombinierten FI/LS- und LS/DI-Schaltern,
:
• GFCI = Ground Fault Circuit Interrupter, ist der in Nordamerika verwendete Begriff für RCCB[11]
https://de.m.wikipedia.org/wiki/Fehlerstrom-Schutzschalter

A residual-current device (RCD), or residual-current circuit breaker (RCCB), is a device to quickly disconnect current to prevent serious harm from an ongoing electric shock. Injury may still occur in some cases, for example if a human falls after receiving a shock. In the United States and Canada, the device is more commonly known as a ground fault circuit interrupter (GFCI), ground fault interrupter (GFI) or an appliance leakage current interrupter (ALCI). In the United Kingdom, these are better known by their initials RCD, and a combined RCD+MCB is known as a RCBO (residual-current circuit breaker with overcurrent protection).
:
Sensitivity
RCD sensitivity is expressed as the rated residual operating current, noted IΔn. Preferred values have been defined by the IEC, thus making it possible to divide RCDs into three groups according to their IΔn value:
• high sensitivity (HS): 6 – 10 – 30 mA (for direct-contact / life injury protection),
• medium sensitivity (MS): 100 – 300 – 500 – 1000 mA (for fire protection),
• low sensitivity (LS): 3 – 10 – 30 A (typically for protection of machine).
Note that the nominal value of residual current indicated above is not an absolute value. More information is presented below.
Break time (response speed)
There are two groups of devices:
• G (general use) for instantaneous RCDs (i.e., without a time delay);
o minimal break time: immediate,
o maximal break time: 200 ms for 1× IΔn, 150 ms for 2× IΔn, and 40 ms for 5× IΔn.
• S (selective) or T (time-delayed) for RCDs with a short time delay (typically used in circuits containing surge suppressors);
o minimal break time: 130 ms for 1× IΔn, 60 ms for 2× IΔn, and 50 ms for 5× IΔn,
o maximal break time: 500 ms for 1× IΔn, 200 ms for 2× IΔn, and 150 ms for 5× IΔn.
https://en.wikipedia.org/wiki/Residual-current_device

Jetzt noch mal speziell zum RCBO (Kombination von FI-Schutzschalter mit Leitungsschutzschalter)

Der Abschaltmechanismus kann auf vier Arten ausgelöst werden:
Auslösung bei Überlast
Wenn der vorgegebene Nennwert des durch den Leitungsschutzschalter fließenden Stromes längere Zeit erheblich überschritten wird, erfolgt die Abschaltung. Die Zeit bis zur Auslösung hängt von der Stärke des Überstroms ab; bei hohem Überstrom ist sie kürzer als bei geringer Überschreitung des Nennstromes. Zur Auslösung wird ein Bimetall verwendet, das sich bei Erwärmung durch den durchfließenden Strom verbiegt und den Abschaltmechanismus auslöst (thermische Auslösung).
Elektromagnetische Auslösung bei Kurzschluss
Tritt in einer Anlage ein Kurzschluss auf, erfolgt die Abschaltung innerhalb weniger Millisekunden durch einen vom Strom durchflossenen Elektromagneten.
Manuelle Auslösung
Für Wartungsarbeiten oder zur vorübergehenden Stilllegung können Stromkreise am Leitungsschutzschalter manuell abgeschaltet werden. Dazu befindet sich ein Kippschalter oder ein Auslöseknopf auf der Frontseite.
Auslösung durch Zusatzmodule
Für die meisten Leitungsschutzschalter namhafter Hersteller gibt es neben Hilfsschaltern auch ansteckbare Unterspannungs- und Arbeitsstromauslöser, FI-Schalter, Störlichtbogen-Schutzeinrichtungen (AFDD) und motorische Antriebe (Wiedereinschaltgeräte), mit deren Hilfe der Leitungsschutzschalter geschaltet werden kann. Die Zusatzmodule werden je nach Leitungsschutzschalter rechts oder links angesteckt.
https://de.m.wikipedia.org/wiki/Leitungsschutzschalter

Der Begriff „thermal time“ bezieht sich hierbei auf die Auslösung bei Überlast.


--------------------------------------------------
Note added at 6 days (2016-05-03 06:50:10 GMT)
--------------------------------------------------

Einzelheiten hierzu siehe https://de.m.wikipedia.org/wiki/Fehlerstrom-Schutzschalter
Selected response from:

Johannes Gleim
Local time: 16:35
Grading comment
Herzlichen Dank Johannes für die ausführlichen Erläuterungen und weiterführenden Links. Für die Verwirrung mit dem 2. Terminus ("current zone") bitte ich um Entschuldigung.
4 KudoZ points were awarded for this answer



Summary of answers provided
4thermische Zeit/Stromzone
gofink
4thermische Ansprechzeit
Johannes Gleim


Discussion entries: 4





  

Answers


20 hrs   confidence: Answerer confidence 4/5Answerer confidence 4/5
thermal time/current zone
thermische Zeit/Stromzone


Explanation:
Master breaker device for back-up protection against electric shock in earthed user units with mains voltage dependent residual current triggering and high selectivity: Figure 1 shows the time / current zones for an acceptable and unacceptable risk of harmful electric shock = Figur 1 zeigt die Zeit/Stromzonen für ein vertretbares und nicht vertretbares Risiko eines schädlichen elektrischen Schlages Z1 -

gofink
Austria
Local time: 16:35
Meets criteria
Specializes in field
Native speaker of: Native in GermanGerman
PRO pts in category: 106

Peer comments on this answer (and responses from the answerer)
neutral  Schtroumpf: Zeichensetzung ist falsch, und so ganz koscher kommt mir das in technischer Hinsicht auch noch nicht vor.
2 hrs
Login to enter a peer comment (or grade)

4 days   confidence: Answerer confidence 4/5Answerer confidence 4/5
thermische Ansprechzeit


Explanation:
Ich denke, dass es sich um eine Verkürzung von "thermal response time" handelt. Das würde nämlich genau zur Funktion eines Fehlerstromschutzschalters passen, so wie ich das als Elektroingenieur kenne.
Elektronik und Elektrotechnik
EN thermal response time
DE thermische Ansprechzeit
http://iate.europa.eu/SearchByQuery.do
http://iate.europa.eu/SearchByQuery.do?method=searchDetail&l...


--------------------------------------------------
Note added at 4 days (2016-04-30 21:53:31 GMT)
--------------------------------------------------

Einzelheiten hierzu siehe https://de.m.wikipedia.org/wiki/Fehlerstrom-Schutzschalter

--------------------------------------------------
Note added at 5 days (2016-05-02 08:52:19 GMT)
--------------------------------------------------

Auszug:

Fehlerstrom-Schutzeinrichtungen jeder Bauform verhindern gefährlich hohe Fehlerströme gegen Erde und tragen so zur Reduzierung lebensgefährlicher Stromunfälle in Niederspannungsnetzen maßgeblich bei. Sie werden grundsätzlich den üblichen Überstromschutzeinrichtungen vorgelagert und zusätzlich zu diesen in den Niederspannungsverteilern installiert. Es gibt auch die Kombination in Form des RCBO, welcher die Funktion der Fehlerstrom-Schutzeinrichtung und des Leitungsschutzschalters in einem Gerät vereint. Für den Fehlerstromschutz einzelner Steckdosen in Altanlagen sind auch RCD-Steckdosen verfügbar.
:
Handelsüblich sind Fehlerstrom-Schutzschalter vom Typ A für Bemessungsfehlerströme von IΔn=10 mA, 30 mA, 100 mA, 300 mA, 500 mA und 1 A.[8] In der Praxis erfolgt die Auslösung bei handelsüblichen RCDs etwa bei 0,8 · IΔn.
Der Nichtauslösefehlerstrom IΔn0 beträgt 0,5 · IΔn. Ein Fehlerstrom-Schutzschalter darf erst oberhalb des halben Bemessungsfehlerstroms auslösen.

Abschaltzeiten:
• Für Fehlerstrom-Schutzschalter ohne Zeitverzögerung betragen die höchstzulässigen Abschaltzeiten 0,3 s bei einem Strom von IΔn, 0,15 s bei 2 · IΔn und 0,04 s bei 5 · IΔn. Damit wird ein Auslösen von (tödlichem) Kammerflimmern sehr unwahrscheinlich, kann allerdings nicht vollkommen ausgeschlossen werden, u. a. weil der physiologische Effekt eines Strompulses von der Phase des Herzschlags abhängt, in die er fällt.
• für selektive Fehlerstrom-Schutzschalter - also mit Zeitverzögerung - betragen die höchstzulässigen Abschaltzeiten 0,5 s bei einem Strom von IΔn, 0,2 s bei 2 · IΔn und 0,15 s bei 5 · IΔn
Nichtauslösezeiten sind nur für selektive Fehlerstrom-Schutzschalter definiert. Die kürzesten Nichtauslösezeiten betragen 0,13 s bei einem Strom von IΔn, 0,06 s bei 2 · IΔn und 0,05 s bei 5 · IΔn.
:
Um Selektivität zu erreichen, können Fehlerstrom-Schutzschalter in Reihe geschaltet werden. Dabei soll nur der dem fehlerbehafteten Stromkreis unmittelbar zugeordnete Fehlerstrom-Schutzschalter ohne Zeitverzögerung auslösen. Dieser Schutzeinrichtung wird zusätzlich ein Fehlerstrom-Schutzschalter mit Zeitverzögerung vorgeschaltet und ist mit dem Symbol für Selektivität gekennzeichnet. Eine Selektivität liegt vor, wenn:
• die kürzeste Nichtauslösezeit des vorgeschalteten Fehlerstrom-Schutzschalters mit Zeitverzögerung höher ist, als die höchste Abschaltzeit des nachgeschalteten Fehlerstrom-Schutzschalters ohne Zeitverzögerung
StörfestigkeitBearbeiten
Um ungewollte Auslösungen zu verhindern, werden Fehlerstrom-Schutzschalter mit Kurzzeitverzögerung verwendet. Ursachen für ungewollte Auslösungen können sein:
• Überspannungen durch Schalthandlungen und atmosphärischen Einwirkungen
• Ladevorgänge nach dem Zuschalten bzw. einer Laständerungen von kapazitiv bzw. induktiv wirkenden Betriebsmitteln
Die höchstzulässigen Abschaltzeiten sind gleich denen von Fehlerstrom-Schutzschaltern ohne Zeitverzögerung. Die Kennzeichnung erfolgt herstellerspezifisch, beispielsweise von:
• ABB mit der Angabe AP-R und der Verwendung des Begriffs kurzzeitverzögert
:
In den internationalen Gerätenormen werden folgende Bezeichnungen verwendet:
• RCCB = Residual Current operated Circuit-Breaker without over current protection, entspricht den reinen FI- bzw. DI-Schaltern, (ist gleichwertig zu RCD residual-current device)
• RCBO = Residual Current operated circuit-Breaker with integral Over current protection, entspricht den kombinierten FI/LS- und LS/DI-Schaltern,
:
• GFCI = Ground Fault Circuit Interrupter, ist der in Nordamerika verwendete Begriff für RCCB[11]
https://de.m.wikipedia.org/wiki/Fehlerstrom-Schutzschalter

A residual-current device (RCD), or residual-current circuit breaker (RCCB), is a device to quickly disconnect current to prevent serious harm from an ongoing electric shock. Injury may still occur in some cases, for example if a human falls after receiving a shock. In the United States and Canada, the device is more commonly known as a ground fault circuit interrupter (GFCI), ground fault interrupter (GFI) or an appliance leakage current interrupter (ALCI). In the United Kingdom, these are better known by their initials RCD, and a combined RCD+MCB is known as a RCBO (residual-current circuit breaker with overcurrent protection).
:
Sensitivity
RCD sensitivity is expressed as the rated residual operating current, noted IΔn. Preferred values have been defined by the IEC, thus making it possible to divide RCDs into three groups according to their IΔn value:
• high sensitivity (HS): 6 – 10 – 30 mA (for direct-contact / life injury protection),
• medium sensitivity (MS): 100 – 300 – 500 – 1000 mA (for fire protection),
• low sensitivity (LS): 3 – 10 – 30 A (typically for protection of machine).
Note that the nominal value of residual current indicated above is not an absolute value. More information is presented below.
Break time (response speed)
There are two groups of devices:
• G (general use) for instantaneous RCDs (i.e., without a time delay);
o minimal break time: immediate,
o maximal break time: 200 ms for 1× IΔn, 150 ms for 2× IΔn, and 40 ms for 5× IΔn.
• S (selective) or T (time-delayed) for RCDs with a short time delay (typically used in circuits containing surge suppressors);
o minimal break time: 130 ms for 1× IΔn, 60 ms for 2× IΔn, and 50 ms for 5× IΔn,
o maximal break time: 500 ms for 1× IΔn, 200 ms for 2× IΔn, and 150 ms for 5× IΔn.
https://en.wikipedia.org/wiki/Residual-current_device

Jetzt noch mal speziell zum RCBO (Kombination von FI-Schutzschalter mit Leitungsschutzschalter)

Der Abschaltmechanismus kann auf vier Arten ausgelöst werden:
Auslösung bei Überlast
Wenn der vorgegebene Nennwert des durch den Leitungsschutzschalter fließenden Stromes längere Zeit erheblich überschritten wird, erfolgt die Abschaltung. Die Zeit bis zur Auslösung hängt von der Stärke des Überstroms ab; bei hohem Überstrom ist sie kürzer als bei geringer Überschreitung des Nennstromes. Zur Auslösung wird ein Bimetall verwendet, das sich bei Erwärmung durch den durchfließenden Strom verbiegt und den Abschaltmechanismus auslöst (thermische Auslösung).
Elektromagnetische Auslösung bei Kurzschluss
Tritt in einer Anlage ein Kurzschluss auf, erfolgt die Abschaltung innerhalb weniger Millisekunden durch einen vom Strom durchflossenen Elektromagneten.
Manuelle Auslösung
Für Wartungsarbeiten oder zur vorübergehenden Stilllegung können Stromkreise am Leitungsschutzschalter manuell abgeschaltet werden. Dazu befindet sich ein Kippschalter oder ein Auslöseknopf auf der Frontseite.
Auslösung durch Zusatzmodule
Für die meisten Leitungsschutzschalter namhafter Hersteller gibt es neben Hilfsschaltern auch ansteckbare Unterspannungs- und Arbeitsstromauslöser, FI-Schalter, Störlichtbogen-Schutzeinrichtungen (AFDD) und motorische Antriebe (Wiedereinschaltgeräte), mit deren Hilfe der Leitungsschutzschalter geschaltet werden kann. Die Zusatzmodule werden je nach Leitungsschutzschalter rechts oder links angesteckt.
https://de.m.wikipedia.org/wiki/Leitungsschutzschalter

Der Begriff „thermal time“ bezieht sich hierbei auf die Auslösung bei Überlast.


--------------------------------------------------
Note added at 6 days (2016-05-03 06:50:10 GMT)
--------------------------------------------------

Einzelheiten hierzu siehe https://de.m.wikipedia.org/wiki/Fehlerstrom-Schutzschalter

Johannes Gleim
Local time: 16:35
Meets criteria
Specializes in field
Native speaker of: German
PRO pts in category: 884
Grading comment
Herzlichen Dank Johannes für die ausführlichen Erläuterungen und weiterführenden Links. Für die Verwirrung mit dem 2. Terminus ("current zone") bitte ich um Entschuldigung.
Login to enter a peer comment (or grade)



Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.

KudoZ™ translation help

The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.


See also:
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search