English term

GFCI

English to Spanish Science Electronics / Elect Eng
Please help me. What is GFCI (I believe it has to do with electricity), and what is its translation into Spanish.
Thanks in advance
Igor

Discussion

Este interruptor es SIN bajada o conexión a tierra.

Proposed translations

+1
3 mins
Selected

ICFT/Interruptor de Circuito con Conexión a Tierra

está en el glosario general...

interruptor de circuito con conexión a tierra

[PDF] Designer Manual K339
Formato de archivo: PDF/Adobe Acrobat - Versión en HTML
... La unidad sólo debe conectarse a un circuito de alimentación protegido por un interruptor
de circuito para fallas puesto a tierra (ICFT), que debe proveer el ...
www.jacuzzi.com/pdf/SPDESIGN.PDF - Páginas similares



--------------------------------------------------
Note added at 2004-01-05 22:07:16 (GMT)
--------------------------------------------------

[PDF] Designer Manual K339
Formato de archivo: PDF/Adobe Acrobat - Versión en HTML
... La unidad sólo debe conectarse a un circuito de alimentación protegido por un interruptor
de circuito para fallas puesto a tierra (ICFT), que debe proveer el ...
www.jacuzzi.com/pdf/SPDESIGN.PDF - Páginas similares

[PDF] Asteria Man K280
Formato de archivo: PDF/Adobe Acrobat - Versión en HTML
Page 1. ASTERIA BATH SERIES INSTALLATION/OPERATING INSTRUCTIONS SERIE
DE TINAS ASTERIA MANUAL DE INSTALACIÓN Y OPERACIÓN Installer ...
www.jacuzzi.com/pdf/ASTERIA.PDF - Páginas similares

Bticino Quinzino - EIMA
... 28DPA, Toma de Corriente Duplex con Placa Oro, $26.30. 28GFR, Toma de Corriente Duplex
con Interruptor de Circuito por Falla a Tierra ICFT con Placa Marfil, $112.85. ...
www.peminet.net/electroiluminacion/ bticino/quinzindex.html - 47k - En caché - Páginas similares

Bticino Quinzino - EIMA
... Toma de Corriente Duplex 2P+T con Interruptor de Circuito por Falla a Tierra ICFT
de Alta Seguridad, se instala en una placa de 4 Modulos, Toma de TV Coaxial, ...
www.peminet.net/electroiluminacion/ bticino/quinvindex.html - 26k - En caché - Páginas similares



Peer comment(s):

agree Luis Rey Ballesteros (Luiroi) : jejeje, gracias por el crédito. Me sorprendió ver mi nombre en tu última línea. ¡Cordiales Saludos!
9 mins
Gracias a ti, Luis!!
Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Thanks everybody for your help!!"
1 hr

Interruptor de Corriente por Falla de Tierra - ICFT

Ground Fault Current Interruptor - GFCI

Corta la corriente al instante; se usa en tomacorrientes cerca de instalaciones hidráulicas (baño - cocina) para mayor seguridad.
Reference:

Exp.

Something went wrong...
16 hrs

Interruptor accionado por corriente de pérdida a tierra

(Ground-fault current interrupter).
(Alternative acronym: GFI - Ground fault interrupter).
Ref. 1:
Collazo's Dictionary says:
Ground-fault interrupter (GFI): interruptor accionado por corriente de pérdida a tierra. (...)

The GFCI is a device that interrupts an electric circuit whenever the ground-fault current exceeds some preset value. This value is lower than the one necessary for tripping overcurrent protection devices (fuses, breakers). Its purpose is to protect individuals against electric shock. Triggering current of GFCI's is usually very small (5 to 100 mA).
In this definition, the word 'current' refers to the ground-fault current that triggers the device, not to the circuit current that is interrupted.
Ref. 2: experience as an electronics engineer.
Something went wrong...
+2
984 days

Disyuntor por fuga a tierra

A ground fault circuit interrupter interrupts the circuit when there is a ground fault. An unintentional electric path between a source of current and a grounded surface is referred to as a "ground-fault." Ground faults occur when current is leaking somewhere, in effect, electricity is escaping to the ground. How it leaks is very important. If your body provides a path to the ground for this leakage, you could electrocuted. A gound fault is a "fuga" (leak) in Spanish. So the correct translation is not that the circuit interrupter is grounded (Interruptor de circuito con conexión a tierra), which it is not, but that the device interrupts the circuit when there is a leak (Disyuntor por fuga a tierra). The word "disyuntor" is more precise (and shorter) than "interruptor de circuito".
Peer comment(s):

agree Juan Nuño : Hola busque este concepto el de GFCI y tu respuesta aunque no es la elejida como la correcta, en efecto lo es, la que se eleigio en la discusion no es correcta, investigue el funcionamiento del device y como lo escribes esta bien dicho, felicidades.
387 days
Gracias, Juan. Me temo que escribí tres años después del comentario original, precisamente porque me pareció que la respuesta elegida no era correcta...
agree Rualina Manzano
1750 days
Something went wrong...
2168 days

interruptor de circuito sin bajada a tierra / sin conexión a tierra

Quiero aclarar que la frase "bajada a tierra" es la que se utiliza en Argentina.
Example sentence:

El interruptor de circuito sin bajda a tierra (GFCI) apaga el ascensor en caso de corto circuito parcial o completo o a causa de sobrecarga de corriente.

Something went wrong...
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search