3 | fire alarm system with multiple sensors (or multiple sensor types) |
| ||
3 | (Fire alarms) placed further apart |
| ||
1 | multi-sensor array fire detection |
|
Discussion entries: 2 | |
---|---|
multi-sensor array fire detection Explanation: multi-sensor array fire detection sources: ieeexplore.ieee.org › document Fire detection with temperature sensor arrays - IEEE Xplore T Kaiser - 2000 - Abstract: We show how to locate a fire in a closed room by an array of sophisticated temperature sensors. Solving this problem enables not only the automatic ... www.semanticscholar.org › paper › Gas-sensor-array-for-reliable-fire-de... [PDF] Gas sensor array for reliable fire detection | Semantic ... Here, we present a gas sensor array composed of different gas sensing technologies for early and robust fire detection. The gas sensor array was placed in a ... www.researchgate.net › publication › 3881033_Fire_detection_with_te... Fire detection with temperature sensor arrays - ResearchGate Download Citation | Fire detection with temperature sensor arrays | We show how to locate a fire in a closed room by an array of sophisticated temperature ... ieeexplore.ieee.org › document Fire detection using a gas sensor array with sensor fusion ... A Solórzano - 2017 - In this work, we investigate the behavior of a gas sensor array coupled to sensor fusion algorithms for fire detection when exposed to standardized fires and ... www.ncbi.nlm.nih.gov › pmc › articles › PMC5855033 Chemical Sensor Systems and Associated Algorithms for Fire ... J Fonollosa - 2018 - Jump to Fire Detectors Incorporating Chemical Sensors - Defined fire regions when smoke detector ... the two considered multi-sensor arrays with ... www.nfpa.org › Symposia › 2017-SUPDET › SUPDET17-Arndt-et-al Multi-criteria / Multi-sensor Early Fire Detection in the ... - NFPA The goal of the reported research is to develop a multi-sensor/multi-criteria early fire detector for the engine compartment of busses. A discrete gas sensor array ... www.researchgate.net › publication › 257354017_Gas_sensor_technolo... Gas sensor technologies for fire detection | Request PDF Gas sensitive field effect transistor (GasFET)-arrays, metal oxide sensors (MOS) and ... Multi-sensor fire detector is a traditional approach to suppresses the ... core.ac.uk › download › pdf Comparison of gas sensor technologies for fire gas detection D Gutmacher - 2011 - Gas sensitive field effect transistor (GasFET)-arrays, metal oxide sensors ... I. Vinage: “Development of a multi-sensor detector for fire detection and life safety. myukk.org › sm_pdf Odor Sensor System for Early Fire Detection and Its ...PDF Y Takei - 2005 - In this paper, an odor sensing system for early fire detection is demonstrated. The odor sensing system consists of a sensor array and a computer. The sensor ... www.mdpi.com › htm Sensors | Free Full-Text | Fire Source Localization Based on ... M Sun - 2016 - Jun 6, 2016 - The main research direction is that sensor arrays with four detectors are used to locate the fire source based on the time-delay estimation ... |
| |
Login to enter a peer comment (or grade) |
Brandlarm med utglesad detektion fire alarm system with multiple sensors (or multiple sensor types) Explanation: Combining more than one detection type within a single unit can reduce the amount of units needed to be installed. https://www.safelincs.co.uk/combined-alarms-with-multiple-se... Svenska: Detektorplacering nämns. I sprinklade byggnader förekommer dock många olika sorters utglesad detektering. Ofta har olika projektörer egna policys som skiljer sig åt med mer än en faktor 2. in https://dokodoc.com/boverkets-remissvarssammansta-llning-til... -------------------------------------------------- Note added at 11 Stunden (2020-02-02 21:14:04 GMT) -------------------------------------------------- or … with multiple detectors or … with multiple detector types |
| |
Login to enter a peer comment (or grade) |
(Fire alarms) placed further apart Explanation: The phrasing "utglesad detektering" seems to refer to the placement of the detectors themselves (which in turn affects their capacity to detect): "Detektorplacering nämns. I sprinklade byggnader förekommer... utglesad detektering." source: https://dokodoc.com/boverkets-remissvarssammansta-llning-til... You can put them further apart because the sprinklers lower the risk associated with doing so. "utglesning av brandposter" clearly refers to putting the fire hydrants at a greater distance from each other: "utglesning av brandposter används... där det föreligger liten risk för omfattande bränder med spridningsrisk." source: https://www.sotenas.se/download/18.212215de15cc395f032d82e8/... |
| |