ARIS SCADA diagnostic signal transmission system Explanation: SCADA systems in general do not represent main control system of the corresponding technology, but focus more on continuous monitoring and parametrization. So the SCADA type of software is operated on a higher level above the hardware (PLCs, I/O modules, dataloggers, sensors, counters, meters ..) that connects and gathers data from the technological processes. SCADA systems are used in all sectors where it is necessary to gather technological data and monitor the correct progression of processes, e.g.: energetics (power plants, heating plants, switchrooms, exchanger stations, ...), manufacturing (production lines, smelting plants, chemical plants, packaging lines, warehouses, ...), building management (HVAC, security, access systems,...), ecology (emissions monitoring, water treatment plants, ...) and many other. https://www.promotic.eu/en/pmdoc/WhatIsPromotic/WhatIsScada.... ARIS CS-M COMMUNICATION CONTROLLER ARIS CS-M communication controller is intended for data acquisition from IEDs and other low-level devices, protocol conversion, data transfer to SCADA and control centers, interaction with other systems in standard protocols. It is used as a part of: Computerized Process Control System of substations, information acquisition and transmission system, technological information acquisition and transmission system, automated system of electric power technical record-keeping, revenue system and many others. Calculation of additional parameters, received from IEDs and other low-level devices Processing of user-defined algorithms including interlocking algorithms Automatic connection establishment with low- and top-level devices Multi-channel and multi-directional protocol conversion of different devices and systems Operation event log generation and management with adjustable size of data change storage for the case of connection loss with top-level control systems Archive data transmission immediately after connection recovery Logging with an adjustable size for data storage Transmission of retrospective data on request from top-level control systems Generation and transmission of diagnostic signals concerning the status of communication links with low-level devices to the top level http://www.nexgenconsultancy.com/CommunicationController.htm... |
| |
Login to enter a peer comment (or grade) |
(See below) Explanation: <...> систему верхнего уровня, представленную программным комплексом ARIS SCADA. -> <...> the top-level system (ARIS SCADA). -------------------------------------------------- Note added at 49 mins (2018-06-27 02:17:39 GMT) -------------------------------------------------- Another option: <...> the top-level system, ARIS SCADA. -------------------------------------------------- Note added at 3 hrs (2018-06-27 04:52:58 GMT) -------------------------------------------------- Страница на оф. сайте разработчика системы: Программный комплекс ARIS SCADA http://www.prosoftsystems.ru/catalog/show/programmnyj-komple... -------------------------------------------------- Note added at 3 hrs (2018-06-27 05:18:34 GMT) -------------------------------------------------- If the customer likes hair splitting, you can translate it as follows: the top-level system based on ARIS SCADA. |
| |
Grading comment
| ||
Login to enter a peer comment (or grade) |
in the form of Explanation: There is only one word in this question: представленный. I would render this as "in the form of". There are other possibilities. |
| |
Login to enter a peer comment (or grade) |
as Explanation: just that a system AS the software ... |
| |
Login to enter a peer comment (or grade) |
which is Explanation: I believe it works here. |
| |
Login to enter a peer comment (or grade) |
47 mins peer agreement (net): +1 |
Reference: where ARIS SCADA software package is installed / represented by ARIS SCADA Reference information: where ARIS SCADA software package is installed / represented by ARIS SCADA https://www.multitran.ru/c/m.exe?l1=2&l2=1&s=%EF%F0%E5%E4%F1%F2%E0%E2%EB%E5%ED%ED%FB%E9 |
| |