GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW) | ||||||
---|---|---|---|---|---|---|
|
17:42 Jan 20, 2016 |
French to English translations [PRO] Tech/Engineering - Electronics / Elect Eng / Power transformers | |||||||
---|---|---|---|---|---|---|---|
|
| ||||||
| Selected response from: Johannes Gleim Local time: 12:31 | ||||||
Grading comment
|
Summary of answers provided | ||||
---|---|---|---|---|
4 +2 | aerial grounding wire mesh (Faraday cage) |
| ||
3 | safety net/netting |
| ||
3 | protective mesh |
|
safety net/netting Explanation: Filet garde-corps, maille 100 mm - Huck https://www.huck-occitania.fr/safety/.../3000-100/ Translate this page Safety net, ,meshsize 100 mm. Zoom. Par m² Filet garde-corps, maille 100 mm ... Filets garde-corps en polypropylène h.r. Ø 5 mm, sans noeuds, maille 60 mm. -------------------------------------------------- Note added at 33 mins (2016-01-20 18:16:36 GMT) -------------------------------------------------- Mise en œuvre des filets de sécurité en grandes ... - Ameli www.ameli.fr/employeurs/prevention/...de.../R446.pdf Translate this page Présentation de l'équipement de travail filet de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 .... Le filet est constitué de matériaux à base de fibres de polypropène. thermobonded - Reverso Context context.reverso.net/traduction/anglais-francais/thermobonded procédé de production d'un non tissé spunbonded constitué de fibres à deux composants ... laminated to one side of a base material (B) which has fine through-holes. Le matériau poreux pour filet est composé d'une feuille poreuse thermocollée ... fine fibre adhered to a thin layer substantially of polypropylene micro fibre. |
| |
Login to enter a peer comment (or grade) |
protective mesh Explanation: www.electricaldigest.co.uk › Fire Detection1 Oct 2015 - ... bonded protective mesh to keep out potential contaminates such as dust ... performancevwmag.com/chrome-improvements/10 Mar 2015 - ... London that I've not even laid eyes on for over a year, let alone made any progress with. .... The power cables are all routed under the engine (wrapped in black protective mesh) |
| |
Login to enter a peer comment (or grade) |
aerial grounding wire mesh (Faraday cage) Explanation: 1.1.2. LE POSTE : SES CONSTITUANTS Le poste est constitué essentiellement : 1) D'appareils haute tension : • Le sectionneur qui a une fonction d'isolement et d'aiguillage • Le disjoncteur qui a une fonction de coupure, mais toujours associé à 1 ou 2 sectionneurs car il ne tient pas lui-même, en position ouverte, avec certitude, certaines situations du réseau (surtension...). • Les réducteurs de mesure de courant (TC) et tension (TT) qui donnent une image aussi fidèle que possible du courant et de la tension HT. • Les parafoudres qui assurent la protection des équipements aux surtensions de foudre et de manœuvres ; Pour leur bon fonctionnement les parafoudres doivent être associés à un filet de garde sur le poste et un câble de garde sur au moins une partie de la ligne et à un circuit de terre de qualité. https://www.google.de/url?sa=t&rct=j&q=&esrc=s&source=web&cd... filet de protection n. safety net http://dictionnaire.reverso.net/francais-anglais/filet Postes à haute et très haute tensions Construction et équipements : 3.4 Protection contre la foudre Des dispositions sont prises pour rendre très improbables des défauts provoqués dans le poste par la foudre : — en limitant les surtensions provenant de coups de foudre sur les lignes (par l’installation d’éclateurs ou de parafoudres) ; — en protégeant le poste contre les coups de foudre directs par un filet de garde constitué par des conducteurs aériens couvrant les installations. Ces dispositifs sont reliés au réseau principal de terre du poste. https://www.google.de/url?sa=t&rct=j&q=&esrc=s&source=web&cd... 9.5.1 Lightning effects in power networks The best know effect of lightning in power transmission or distribution networks is the direct lightning stroke either on a phase conductor or on a tower (or ground conductor). The protection of overhead lines against direct strikes is achieved by grounding wires mounted on towers where the wire is grounded. : 9.5.2 Lightning effects on power network substation equipment Here again direct and indirect stroke effects can take place …. The substation ground is usually a metallic mesh buried at 30-50 cm under the earth’s surface. Any lightning current hitting an overhead line entering the substation will be conducted to the ground by the arrester usually installed at the entrance of the substation. … https://books.google.de/books?id=2b3_IztUdmEC&pg=PA490&lpg=P... In order to prevent steep surges form entering an HV/MV substation, the HV lines are equipped with earth wires. Earth wires on MV lines close to the substation also assist. If the MV-line crossarms are earthed, this limits the overvoltage level which can be formed on the line. Often larger substations are themselves equipped with earth wires or masts to protect the substation from direct lightning strikes. https://books.google.de/books?id=TpW28vHkE-0C&pg=PA138&lpg=P... In an electrical substation a ground (earth) mat is a mesh of conductive material installed at places where a person would stand to operate a switch or other apparatus; it is bonded to the local supporting metal structure and to the handle of the switchgear, so that the operator will not be exposed to a high differential voltage due to a fault in the substation. https://en.wikipedia.org/wiki/Ground_(electricity) protection level 1 The purpose of level 1 protection is to limit the effects of direct impacts on electrical installations by diverting the lightning current to the desired locations. Controlled diversion of lightning current to precise points is possible using: • lightning rods implementing the striking distance principle. These thin rods are placed at the top of the structure requiring protection and connected to earth by the most direct path (via conductors descending around the protected structure and connected to the earthing network). Observations have shown that a good protection against direct lightning strikes is provided in a cone with its summit at the top of the lightning rod and extending downward at 45° angles with respect to the vertical. • Faraday cages or shields which consist of closed grids of horizontal and vertical conductors connected to an earthing network. The mesh size must be less than 15 m and vertical rods are placed at the nodes on the top part. Coverage of the zone requiring protection is equivalent to that provided by a multitude of lightning rods. In either case, lightning rods or cages, the electro-geometrical model determines the protected zone using the fictive sphere method. The point of impact of the lightning strike is determined by the first object on the ground falling within the striking distance d of the leader. https://www.google.de/url?sa=t&rct=j&q=&esrc=s&source=web&cd... Abstract: In this paper we propose a new formalism for analyzing the transient behavior of grounding systems associated to substation structures (Faraday-cage) under lightning strokes in transient regime. The protective device to study is formed of an aerial wire mesh connected to a grounding grid by simple conductors called down conductors. : Our system is constituted of several types of conductors, the resolution of the propagation equation requires the knowledge of the per unit length parameters of both of the buried grid, the down conductors and the aerial wi https://www.google.de/url?sa=t&rct=j&q=&esrc=s&source=web&cd... Air-termination systems can consist of the following components and can be combined with each other as required: ⇒ Rods ⇒ Spanned wires and cables ⇒ Intermeshed conductors : Mesh method A “meshed” air-termination system can be used universally regardless of the height of the structure and shape of the roof. A reticulated air-termination network with a mesh size according to the class of lightning protection system is arranged on the roofing (Table 5.1.1.3). : Fig. 5.1.1.21 Isolated external lightning protection system, consisting of two separate air-termination masts, connected by a horizontal air-termination conductor: Projection on a vertical surface via the two masts (vertical section) https://www.google.de/url?sa=t&rct=j&q=&esrc=s&source=web&cd... Ground wires bridging a substation from HV side to MV side, see slide 44 http://de.slideshare.net/MohammedZaidShaikh1/high-voltage-53... |
| |
Grading comment
| ||
Login or register (free and only takes a few minutes) to participate in this question. You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy. KudoZ™ translation helpThe KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.
See also: Search millions of term translations Your current localization setting
English
Select a language Close search
|