GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW) | ||||||
---|---|---|---|---|---|---|
|
09:25 May 2, 2015 |
English to Polish translations [PRO] Tech/Engineering - Energy / Power Generation / power turbine | |||||||
---|---|---|---|---|---|---|---|
|
| ||||||
| Selected response from: mike23 Poland Local time: 05:49 | ||||||
Grading comment
|
Summary of answers provided | ||||
---|---|---|---|---|
1 +1 | fundament; baza; piedestał; podstawa; postument |
| ||
2 | podstawa montażowa |
|
fundament; baza; piedestał; podstawa; postument Explanation: 1.2.2 Underbase • Turbine underbase – fabricated carbon steel construction, arranged for multi-point mounting • Integral lubricating oil tank – carbon steel • Generator and gearbox underbase – fabricated carbon steel construction, arranged for multi-point mounting • Support legs – underbase to ground, fixed on installation to carry all static and dynamic loads http://cfaspower.com/TechnicalSGT400_Mobile_Genset.pdf - page 5 |
| |
Login to enter a peer comment (or grade) |
podstawa montażowa Explanation: podstawa montażowa Tu zdjęcia -> Generator Underbase http://www.alibaba.com/product-detail/Generator-Underbase_60... -------------------------------------------------- Note added at 5 hrs (2015-05-02 14:51:14 GMT) -------------------------------------------------- http://www.rilmac.co.uk/services/fabrication/underbase-fabri... -------------------------------------------------- Note added at 21 hrs (2015-05-03 06:32:21 GMT) -------------------------------------------------- For many years, Rilmac Fabrication have specialised in manufacturing complex finished machined underbase/base plates/bedplate fabrications. We have provided these for customers worldwide within the Oil and Gas, Power Generation and General Engineering Sectors. Rilmac have implemented and perfected stringent working practices and procedures to reduce potential leak paths within the integral lube oil tank compartments. Anchored, levelled assembly frames ensure the flatness of the units are maintained. Correct joint fit up of the main structural sections is critical during the build sequence. Excessive mismatch can provide stress concentration points which lead to fatigue cracks and subsequent leak paths to the integral lube oil tank within the underbase fabrications. -------------------------------------------------- Note added at 21 hrs (2015-05-03 06:39:25 GMT) -------------------------------------------------- Turbina kondensacyjna, przekładnia planetarna i generator umieszczone są na wspólnej ramie, zbiornik olejowy jest również zintegrowany z ramą. ...Rama służy za płytę fundamentową. http://www.powerelectric.com.pl/wp-content/uploads/2012/06/r... -------------------------------------------------- Note added at 21 hrs (2015-05-03 06:44:47 GMT) -------------------------------------------------- Opcja 2: rama / rama nośna / rama montażowa / rama (fundamentowa) pod turbinę rama pod turbinę, przekładnię, generator https://metalexpert.pl/wp-content/uploads/2014/01/zapytanie_... Rama pod turbinę i przekładnię http://www.powerelectric.com.pl/turbozespoly-z-turbinami-par... Główna lub osobna rama fundamentowa http://www.kierunekenergetyka.pl/Resources/art/6084/bmp_5236... |
| |
Grading comment
| ||
Login to enter a peer comment (or grade) |
Login or register (free and only takes a few minutes) to participate in this question.
You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.