creeping opens and shorts

French translation: ouverture et court-circuits à résistance accroissante (incrémentante, augmentante)

GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW)
English term or phrase:creeping opens and shorts
French translation:ouverture et court-circuits à résistance accroissante (incrémentante, augmentante)
Entered by: Johannes Gleim

08:38 Mar 20, 2015
English to French translations [PRO]
Tech/Engineering - Electronics / Elect Eng
English term or phrase: creeping opens and shorts
Article sur les systèmes de sécurité et la norme EN 54-13:

To further increase reliability and availability of the transmission paths in XXX environments, YYY has also developed a family of active end-of-line (EOL) modules. They act as line terminators that continuously test 2- and
4-wire transmission paths for ***creeping opens and shorts*** according to the procedures and criteria of acceptance as laid out in the norm EN 54-13.
Yves Cromphaut
Belgium
Local time: 19:30
ouverture et court-circuits à résistance accroissante (incrémentante, augmentante)
Explanation:
NF EN 54-13 Août 2005
Systèmes de détection et d'alarme incendie - Partie 13 : évaluation de la compatibilité des composants d'un système -
http://www.boutique.afnor.org/norme/nf-en-54-13/systemes-de-...

Area Rotating machinery / Operation
IEV ref 411-52-44
en
creeping (of a d.c. motor)
the undesired running at slow speed of a d.c. motor due to residual magnetism
fr
rampage (d'un moteur à courant continu)
fonctionnement indésirable à faible vitesse d'un moteur à courant continu dû au magnétisme rémanent
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...
http://iate.europa.eu/SearchByQuery.do?method=searchDetail&l...

Do not mismatch « creeping by « creepage ».

Area Electrical and magnetic devices / Behaviour and use
IEV ref 151-15-50
en
creepage distance
shortest distance along the surface of a solid insulating material between two conductive parts
fr
ligne de fuite, f
distance la plus courte, le long de la surface d'un isolant solide, entre deux parties conductrices
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...

Test Resistance
Aiming to increase reliability through early detection of creeping shorts and opens, EN 54-13 introduced defined procedures and criteria of acceptance for the functional tests of fault warning conditions in transmission paths. The test for a creeping open requires the introduction of serial resistance into the transmission path. Starting with the quiescent condition, the resistance must be increased until a fault warning condition is reached and a fault is signaled to the fire panel. Decreasing the resistance by 10% must then make the entire transmission path fully operational again.
This means that all elements that are connected to the tranmission paths remain fully functional, even if elements require higher current values in alarm state compared to the normal state. By the EOL modules it is assured that the line resistances on the tranmission paths are within the limits that are required for flawless functionality. The creeping short test is very similar, requiring parallel resistances. Here, the resistance needs to be reduced until a fault is signaled, and a subsequent increase of the resistance by 10% must bring the transmission path back to normal.
End of The Line
In order to comply with the requirements of EN 54-13, and thus be able to connect detector lines to the fire alarm system in a way that conforms to this standard, XXX has developed a family of active end-of-line (EOL) modules. They act as line terminators that continuously test 2 and 4-wire transmission paths for creeping opens and shorts according to the procedures and criteria of acceptance as laid out in the norm.
http://www.git-security.com/topstories/fire-protection/makin...

Tyco Fire & Integrated Solutions SA / ADT est l‘un des premiers fabricants à obtenir la reconnaissance des systèmes selon EN 54-13 (évaluation de la compatibilité des composants du système) pour les systèmes d‘alarme incendie de la série MZX.
http://www.fr.tyco.ch/document-downloads/Prospekte/Detector/...

-Simple défaut
Simple défaut sur un circuit ouvert ou un circuit fermé (bouclé) d’entrées/sorties (détecteurs, boutons, sirènes, modules de commande, ...) Le système doit être conçu de telle manière qu’un simple défaut à l’endroit le plus défavorable dans un circuit ne puisse pas empêcher le bon fonctionnement de plus d’une des fonctions suivantes:
o la détection incendie automatique;
o le fonctionnement des déclencheurs manuels;
o la diffusion sonore d’une alarme incendie;
o la transmission ou la réception de signaux de et vers les dispositifs d’entrée et de sortie;
o l’activation d'équipements auxiliaires
:
o la simulation des différents défauts possibles (détecteurs retirés de leur socle, réseau ouvert, réseau en court-circuit, ouverture de lignes de sirènes, coupure des sources d'alimentation, coupure du rayon de détection d'un beam, fonctionnement du mode dégradé, encrassement d'un détecteur...) et vérification de la signalisation adéquate des défauts
http://www.cifful.ulg.ac.be/images/stories/Guides_secu_incen...

RÈGLES TECHNIQUES T7
SYSTÈMES DE DÉTECTION AUTOMATIQUE D’INCENDIE
SPÉCIFICATIONS ET MÉTHODES D’ESSAIS
:
7.4.1 Programme d’essais
Les essais sont réalisé selon le § 5.3 de la EN 54-13. Cependant les essais réalisés en laboratoire de coupure de de court-circuit impédant ne s’applique qu’aux circuits de détection aux sens de la norme EN 54-2.
http://www.google.de/url?sa=t&rct=j&q=&esrc=s&source=web&cd=...

Explication de mot « impédant » :
Area Earthing and protection against electric shock / Operation
IEV ref 195-04-08
en
impedance earthed neutral system
impedance grounded neutral system (US)
system in which at least one neutral point is earthed through a device having an impedance designed to limit the line-to-earth short-circuit current
fr
réseau à neutre impédant
réseau dont au moins un point neutre est mis à la terre par l’intermédiaire d’un dispositif présentant une impédance conçue pour limiter le courant de court-circuit phase-terre
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...

• Afin d'utiliser le système de détection d'incendie conformément à la norme EN 54-13, il est nécessaire
d'interrompre la connexion entre chaque zone conventionnelle et les modules EOL.
• Il convient de respecter la résistance de ligne maximale de 25 Ω pour les lignes conventionnelles avec déclencheurs manuels d'alarme incendie ou détecteurs d'incendie automatiques
http://resource.boschsecurity.com/documents/FLM_420_4_CON_Da...

Remarque!
Notez que la résistance de ligne pour les sorties de relais est limitée à 22,5 ohms
http://resource.boschsecurity.com/documents/Panel_Installati...

Malheureusement, pas de description d'essais détaillée trouvé.
Selected response from:

Johannes Gleim
Local time: 19:30
Grading comment
Merci
4 KudoZ points were awarded for this answer



Summary of answers provided
3 -1ouverture et court-circuits à résistance accroissante (incrémentante, augmentante)
Johannes Gleim


Discussion entries: 10





  

Answers


3 hrs   confidence: Answerer confidence 3/5Answerer confidence 3/5 peer agreement (net): -1
ouverture et court-circuits à résistance accroissante (incrémentante, augmentante)


Explanation:
NF EN 54-13 Août 2005
Systèmes de détection et d'alarme incendie - Partie 13 : évaluation de la compatibilité des composants d'un système -
http://www.boutique.afnor.org/norme/nf-en-54-13/systemes-de-...

Area Rotating machinery / Operation
IEV ref 411-52-44
en
creeping (of a d.c. motor)
the undesired running at slow speed of a d.c. motor due to residual magnetism
fr
rampage (d'un moteur à courant continu)
fonctionnement indésirable à faible vitesse d'un moteur à courant continu dû au magnétisme rémanent
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...
http://iate.europa.eu/SearchByQuery.do?method=searchDetail&l...

Do not mismatch « creeping by « creepage ».

Area Electrical and magnetic devices / Behaviour and use
IEV ref 151-15-50
en
creepage distance
shortest distance along the surface of a solid insulating material between two conductive parts
fr
ligne de fuite, f
distance la plus courte, le long de la surface d'un isolant solide, entre deux parties conductrices
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...

Test Resistance
Aiming to increase reliability through early detection of creeping shorts and opens, EN 54-13 introduced defined procedures and criteria of acceptance for the functional tests of fault warning conditions in transmission paths. The test for a creeping open requires the introduction of serial resistance into the transmission path. Starting with the quiescent condition, the resistance must be increased until a fault warning condition is reached and a fault is signaled to the fire panel. Decreasing the resistance by 10% must then make the entire transmission path fully operational again.
This means that all elements that are connected to the tranmission paths remain fully functional, even if elements require higher current values in alarm state compared to the normal state. By the EOL modules it is assured that the line resistances on the tranmission paths are within the limits that are required for flawless functionality. The creeping short test is very similar, requiring parallel resistances. Here, the resistance needs to be reduced until a fault is signaled, and a subsequent increase of the resistance by 10% must bring the transmission path back to normal.
End of The Line
In order to comply with the requirements of EN 54-13, and thus be able to connect detector lines to the fire alarm system in a way that conforms to this standard, XXX has developed a family of active end-of-line (EOL) modules. They act as line terminators that continuously test 2 and 4-wire transmission paths for creeping opens and shorts according to the procedures and criteria of acceptance as laid out in the norm.
http://www.git-security.com/topstories/fire-protection/makin...

Tyco Fire & Integrated Solutions SA / ADT est l‘un des premiers fabricants à obtenir la reconnaissance des systèmes selon EN 54-13 (évaluation de la compatibilité des composants du système) pour les systèmes d‘alarme incendie de la série MZX.
http://www.fr.tyco.ch/document-downloads/Prospekte/Detector/...

-Simple défaut
Simple défaut sur un circuit ouvert ou un circuit fermé (bouclé) d’entrées/sorties (détecteurs, boutons, sirènes, modules de commande, ...) Le système doit être conçu de telle manière qu’un simple défaut à l’endroit le plus défavorable dans un circuit ne puisse pas empêcher le bon fonctionnement de plus d’une des fonctions suivantes:
o la détection incendie automatique;
o le fonctionnement des déclencheurs manuels;
o la diffusion sonore d’une alarme incendie;
o la transmission ou la réception de signaux de et vers les dispositifs d’entrée et de sortie;
o l’activation d'équipements auxiliaires
:
o la simulation des différents défauts possibles (détecteurs retirés de leur socle, réseau ouvert, réseau en court-circuit, ouverture de lignes de sirènes, coupure des sources d'alimentation, coupure du rayon de détection d'un beam, fonctionnement du mode dégradé, encrassement d'un détecteur...) et vérification de la signalisation adéquate des défauts
http://www.cifful.ulg.ac.be/images/stories/Guides_secu_incen...

RÈGLES TECHNIQUES T7
SYSTÈMES DE DÉTECTION AUTOMATIQUE D’INCENDIE
SPÉCIFICATIONS ET MÉTHODES D’ESSAIS
:
7.4.1 Programme d’essais
Les essais sont réalisé selon le § 5.3 de la EN 54-13. Cependant les essais réalisés en laboratoire de coupure de de court-circuit impédant ne s’applique qu’aux circuits de détection aux sens de la norme EN 54-2.
http://www.google.de/url?sa=t&rct=j&q=&esrc=s&source=web&cd=...

Explication de mot « impédant » :
Area Earthing and protection against electric shock / Operation
IEV ref 195-04-08
en
impedance earthed neutral system
impedance grounded neutral system (US)
system in which at least one neutral point is earthed through a device having an impedance designed to limit the line-to-earth short-circuit current
fr
réseau à neutre impédant
réseau dont au moins un point neutre est mis à la terre par l’intermédiaire d’un dispositif présentant une impédance conçue pour limiter le courant de court-circuit phase-terre
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...

• Afin d'utiliser le système de détection d'incendie conformément à la norme EN 54-13, il est nécessaire
d'interrompre la connexion entre chaque zone conventionnelle et les modules EOL.
• Il convient de respecter la résistance de ligne maximale de 25 Ω pour les lignes conventionnelles avec déclencheurs manuels d'alarme incendie ou détecteurs d'incendie automatiques
http://resource.boschsecurity.com/documents/FLM_420_4_CON_Da...

Remarque!
Notez que la résistance de ligne pour les sorties de relais est limitée à 22,5 ohms
http://resource.boschsecurity.com/documents/Panel_Installati...

Malheureusement, pas de description d'essais détaillée trouvé.

Johannes Gleim
Local time: 19:30
Specializes in field
Native speaker of: German
PRO pts in category: 339
Grading comment
Merci

Peer comments on this answer (and responses from the answerer)
agree  Tony M: Apologies, you are right and I was wrong; inadequate original context to work from! Presumably, though, the 'augmentant' only applies to the open; I imagine the short is in fact a reducing resistance?
26 mins
  -> Thank you! The only question is, how to translate "creeping". I hesitated to apply "rampant lentement" or other circumscriptions.

disagree  Herbie: "ouverture accroissante"?- Does this term exist at all? At least not in electrical engineering.
1 hr
  -> This is not the question. It describes the process of deterioration of creepages. The asker is free to rephrase my idea (accroissante, incrémentante, augmentante)

disagree  GILLES MEUNIER: accroissante, ce n'est pas du français
8 days
  -> 379.000 Ghits. Voir la discussion. Par ailleurs, « accroissante (incrémentante, augmentante » sont des suggestions seulement, illustrant le type de détérioration.
Login to enter a peer comment (or grade)



Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.

KudoZ™ translation help

The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.


See also:
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search