GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW) | ||||||
---|---|---|---|---|---|---|
|
06:40 Apr 18, 2014 |
English to Polish translations [PRO] Science - Energy / Power Generation / linie napowietrzne | |||||||
---|---|---|---|---|---|---|---|
|
| ||||||
| Selected response from: Crannmer Local time: 02:00 | ||||||
Grading comment
|
Summary of answers provided | ||||
---|---|---|---|---|
4 | filtr zaporowy dla częstotliwości nośnych |
| ||
2 +1 | dławik zaporowy |
|
Summary of reference entries provided | |||
---|---|---|---|
PLC (Power Line Carrier) Line Trap |
|
dławik zaporowy Explanation: propozycja Example sentence(s):
Reference: http://zoen.pl/index.php?a=s&dict&language=pl Reference: http://tinyurl.com/os8lml6 |
| |
Login to enter a peer comment (or grade) |
filtr zaporowy dla częstotliwości nośnych Explanation: filtr zaporowy dla częstotliwości nośnych Bez ograniczania konstrukcji filtra do dławika (cewki indukcyjnej), szczególnie, ze te filtry zwykle są wykonane przynajmniej jako LC. Patrz rozdział "Łącza wielkiej częstotliwości (w.cz.)" w: Przesył informacji w sieciach energetycznych wysokiego napięcia http://www.elektrycy.cba.pl/nauka/informatykawelektroenerget... -------------------------------------------------- Note added at 2 Stunden (2014-04-18 09:06:56 GMT) -------------------------------------------------- W linkowanym dokumencie są schematy zarówno linii przesyłowych, jak i urządzeń komunikacyjnych. Winno dać się dopasować. |
| |
Grading comment
| ||
Login to enter a peer comment (or grade) |
1 hr |
Reference: PLC (Power Line Carrier) Line Trap Reference information: A line trap (high-frequency stopper) is a maintenance-free parallel resonant circuit, mounted inline on high voltage AC transmission power lines to prevent the transmission of high frequency (40 kHz to 1000 kHz) carrier signals of power line communication to unwanted destinations. The inductive reactance of the line trap presents a high reactance to high-frequency signals but a low to mains frequency. The major components of a line trap are: Main coil (air-core dry-type power inductor) Tuning device. Adjust blocking frequency or bandwidth, consist of coils, capacitors and resistors. Self-tuned Line Traps do not require the use of tuning devices. Protective device connected in parallel with the main coil and the tuning device protects them by reducing the transient overvoltages. http://new.abb.com/network-management/communication-networks... http://www.alstom.com/grid/products-and-services/high-voltag... http://en.wikipedia.org/wiki/High_frequency_line_trap -------------------------------------------------- Note added at 2 hrs (2014-04-18 09:14:15 GMT) -------------------------------------------------- http://encyclopedia.maksiu.info/haslo/Dławik_zaporowy |
| |
Login to enter a peer comment (or grade) |
Login or register (free and only takes a few minutes) to participate in this question.
You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.