French to English translations [PRO] Tech/Engineering - Electronics / Elect Eng / Substation and power line | |||||||
---|---|---|---|---|---|---|---|
|
| ||||||
| Selected response from: Johannes Gleim Local time: 08:37 | ||||||
Grading comment
|
Summary of answers provided | ||||
---|---|---|---|---|
4 +1 | full circle phase(angular) shift of the electrical current |
| ||
4 | current pulsations (oscillations) |
| ||
2 | electric deviation |
|
electric deviation Explanation: / |
| |
Login to enter a peer comment (or grade) |
current pulsations (oscillations) Explanation: If this is no typing error for « détours électrique » I would interpret « tours » in standard terms as revolutions. IEV ref 113-01-45 en revolution non-SI unit of angle of rotation, equal to 2π rad Note: The unit revolution is widely used in specifications on rotating machines fr tour, m unité d’angle de rotation en dehors du SI, égale à 2π rad Note : Le tour est largement utilisé dans les spécifications de machines tournantes http://www.electropedia.org/iev/iev.nsf/display?openform&iev... In fact, it is possible to read « L’ouverture d’une ligne ne doit notamment pas entraîner de tour électrique » as « Opening of one line must not trigger any turning/rotation/revolution of the load », as this would lead to current pulsations (« electric revolutions », i.e. electric oscillations) from the rotating machine (alternator). IEV ref 411-52-32 en current pulsation the difference between maximum and minimum amplitude of the motor current during a single cycle corresponding to one revolution of the driven load expressed as a percentage of the average value of the current during this cycle NOTE – For a.c. motors, all currents in this definition are r.m.s. currents. fr pulsation de courant différence entre les valeurs maximale et minimale d'un courant d'un moteur pendant le cycle correspondant à un tour de la charge entraînée, exprimée en pourcentage de la valeur moyenne du courant pendant ce cycle NOTE – Pour les moteurs à courant alternatif, les valeurs de courant sont des valeurs efficaces. http://www.electropedia.org/iev/iev.nsf/display?openform&iev... -------------------------------------------------- Note added at 3 hrs (2012-10-11 00:36:08 GMT) -------------------------------------------------- Annex: the rotating machine may be an alternator or a motor. The effect would be similar. -------------------------------------------------- Note added at 3 hrs (2012-10-11 00:37:03 GMT) -------------------------------------------------- And transformes behaves in the same way. |
| |
Grading comment
| ||
Login to enter a peer comment (or grade) |
full circle phase(angular) shift of the electrical current Explanation: or rotation of the phase shift? An alternative electrical current is an oscillatory movement; see "Mathematics of AC voltages" in [http://en.wikipedia.org/wiki/Alternating_current] the oscillation on both side of the connection between the production unit and the grid should be synchronised - if they are not there is an angular shit (décalage de phase), a rotation/shift of the phase of one current in relation to the other. Could probably be better explained, and there might be some other usual term, but that's what it is. inversion de puissance: the two currents are in opposed phases => phase shift = 180 degrees (half-circle) "3.7.4 Comportement en cas de rupture de synchronisme [Champ d’application: installations avec des machines synchrones] [Si l’installation est d’une puissance inférieure ou égale à 120 MW :] [Le critère de détection de la rupture de synchronisme dépendra de la protection installée par le producteur. A adapter en conséquence.] L’installation doit se découpler dès la détection d’une perte de synchronisme, c’est à dire dès lors qu’un tour électrique d’angle interne ou une inversion de puissance est atteint. [Si l’installation est d’une puissance Pmax supérieure à 120 MW :] Conformément à l’article 23 III. de l’arrêté [2], en cas de rupture fortuite du synchronisme avec le RPT, l’installation doit disposer d’une capacité constructive à supporter sans dommage avant de se déconnecter : • 4 tours d’angle interne ; • 20 inversions de puissance. La séparation du réseau intervenant dès que l’un ou l’autre des 2 critères est atteint. Néanmoins, en cas de rupture de synchronisme suite à un défaut sur le système d’excitation, l’installation peut se déconnecter sans délai." [http://clients.rte-france.com/htm/fr/mediatheque/telecharge/...] -------------------------------------------------- Note added at 14 hrs (2012-10-11 12:01:42 GMT) -------------------------------------------------- sorry "... the oscillations on both side of the connection ..." |
| |
Login to enter a peer comment (or grade) |